| GENERAL
MAINTENANCE & SET UP FOR GO KNIVES
DISCONNECT
AIR SUPPLY WHEN SERVICING THE UNIT!
BLADE REPLACING INSTRUCTIONS
Remove the low head socket cap screws (#16),
replace blades (#03 & #04) and reinstall
screws. Follow the instructions listed below
for readjusting.
BLADE
SETTING INSTRUCTIONS
1. Loosen the two low head socket cap screws
(#16),
2.
Close the movable blade (#3) down over the stationary
blade (#4).
3.
Tighten (as you face the blade, cylinder up)
the left low head socket cap screw (#16), then
open one turn to make the blade parallel to
the bracket.
4.
Adjust the right low head socket screw to allow
two business cards to slip between the wide
side of the movable blade and the stationary
blade.
5.
Now that the blade is set, test the knife with
hand pressure. Movement should be smooth with
a light consistent force needed to move the
blade across the stationary blade.
6.
Test cut a piece of paper to make sure the settings
are proper.
TROUBLESHOOTING
1. If the knife remains at its home (up) position
or does not return to its home position:
a)
Check that at least 40 PSI air is supplied.
b)
Check that there are no obstructions in the
way of the knife assembly.
c)
Remove the movable blade and check for smooth
operation of the blade bracket. If a problem
exists isolate the cylinder (#11) or bearings
(#13) to see where the problem is.
2.
If the knife does not cut product properly:
a)
Check that there are no obstructions in the
way of the knife assembly.
b)
Increase air pressure to cut tougher materials.
c)
Resharpen or replace blades.
3.
If the knife does not cut product, movable blade
deflects and bends material:
a)
Slightly higher preload is necessary on the
movable blade. Tighten each of the low head
socket cap screws (#16) slightly1/4 turn. Make
sure each is turned in the same amount.
Note:
Increasing the blade preload will shorten the
blade, bearing, and cylinder life.
WARNING!
!
UNIT